Electrode Resistance Measurement Systems - RM2610 - HIOKI
Quantify composite layer resistance
Interface resistance in Li-ion battery electrode sheets
Measurement parameters Composite resistivity [Ωcm]
Information necessary for computation
Composite layer thickness [μm] (for 1 side)
Current collector thickness [μm]
Current collector volume resistivity [Ωcm]
Measurement current:1μA(min.) to 10mA(max.)
For more details refer datasheet.
|
Resistance Hitester - RM3542, RM3542A - HIOKI
Measure in as Fast as 0.9 ms,Optimized for Automated Systems
Resistance range:100mΩ range to 100MΩ range,10 steps
[at Low Power ON] 1000 mΩ range to 1000 Ω range,4 steps
Display:Monochrome graphic LCD 240 × 64 dot,LED backlight
Testing current: 100mA DC to 100nA DC
Open-terminal voltage:20 V DC max.
Sampling rate:FAST, MEDIUM, SLOW,3 settings
Power supply:100 to 240V AC,50/60Hz,30VA max.
For more details refer datasheet.
|
Resistance HITester - RM3543 - HIOKI
Resistance Meter for Ultra-low and Low Shunt Resistance
Measurement method Four-terminal, constant-current DC
Resistance range:10mΩ to 1000Ω range,7steps
Display:Monochrome graphic LCD 240 × 64 dot
Measurement accuracy:±0.060 % rdg. ±0.001 % f.s.
Testing current:1A DC to 1mA DC
Open-terminal voltage:20V DC max.
Sampling rate:FAST,MEDIUM,SLOW,3settings
For more details refer datasheet.
|
Resistance Meter - RM3545A - HIOKI
New Heights in 100% Inspection.
Market leading precision tests for testing
every weld or connection on your production line.
Testing current (Measurement current):
High mode: 1000μΩ (1 A) to 1000 MΩ (up to 1 μA)
Low mode: 100 mΩ (100 mA) to 100 Ω (1 mA)
Low power mode (LP): Low power measurement with current
and open circuit voltage down to 20 mV
LP1000 mΩ (1 mA) to LP1000 Ω (5 μA)
For more details refer datasheet.
|
Resistance Meter - RM3548 - HIOKI
Portable Resistance Meter Measures from µΩ to MΩ
Resistance range:3mΩ to 3MΩ range,10steps
Measurement accuracy: ±0.020 % rdg. ±0.007 % f.s.
Testing current : 1A DC to 500nA DC
Open-terminal voltage5.5 V DC max.
Temperature measurement:-10.0 to 99.9°C,
accuracy: ±0.50°C
Measurement speed:Fixed
For more details refer datasheet.
|
Super Megohm Meter - SM7110 - HIOKI
Rapid 6.4ms Super Megohm and Low Current Testing
Number of channels:1 ch
DC current measurement
20pA range (0.1 fA resolution),
Accuracy: ±(2.0 % of rdg. +30 dgt.)
200 pA range (1.0 fA resolution),
Accuracy: ±(1.0 % of rdg. +30 dgt.)
2 nA range (10 fA resolution),
For more details refer datasheet.
|
Super Megohm Meter - SM7120 - HIOKI
Rapid 6.4ms Super Megohm and Low Current Testing
Number of channels:1ch
DC current measurement
20 pA range (0.1 fA resolution),
Accuracy: ±(2.0 % of rdg. +30 dgt.)
200 pA range (1.0 fA resolution),
Accuracy: ±(1.0 % of rdg. +30 dgt.)
For more details refer datasheet.
|
Super Megohm Meter - SM7420 - HIOKI
4ch micro current model
perfect for automated-systems integration
Number of channels:4 ch
DC current measurement
20 pA range (0.1 fA resolution),
Accuracy: ±(2.0 % of rdg. +30 dgt.)
200 pA range (1.0 fA resolution),
Accuracy: ±(1.0 % of rdg. +30 dgt.)
2 nA range (10 fA resolution),
For more details refer datasheet.
|