Our Products

Current/Voltage Transducer - Con I/Con V - RISHABH
Product Overview

The RISH CON-V/RISH CON-I is used to measure 
and convert AC Voltage or Current input into 
an proportional DC current or voltage output signal. 
Output signal generated is proportional to the root
mean square value of the input Current or Voltage.
Analog Output (Single or dual)
Isolated analog output which can be set onsite 
to either voltage or current output. 
Programmable Input/Output
Onsite transducer can be programmed using front key 
& display or through programming port or through RS 485.
For more details please refer datasheet.

Frequency Transducer - Rish Con Hz - RISHABH
Product Overview

The Rish CON-Hz transducer is used for frequency measurement. 
The output signal is proportional to measured frequency 
and is either load independent DC Current 
or load independent DC Voltage
Fully onsite programmable input range
Available in Single or Dual output type
Onsite selectable output type.(DC current/DC voltage) 
Accuracy class 0.2 ( IEC / EN 60688)
l RS 485(Modbus) Communication (Optional)
l Connection Terminal : Conventional Screw type
l Seven Segment LCD Display (Optional)
For more details please refer datasheet.

Power Transducer - Rish Con P - RISHABH
Product Overview

The Rish CON-P transducer is used to measure
and convert active,reactive,apparent power,Phase 
angle & Power Factor of a Single-phase or 
Three-phase AC system with balanced or unbalanced 
load into a proportional load independent DC current
or voltage output signal.
Onsite selectable output type(DC current / DC voltage)
Accuracy Class 0.2 (IEC / EN 60688) for Power
On Site Configurable as Active/Reactive/Apparent Transducer
/Phase Angle/Power Factor
Seven Segment LCD Display (Optional)
For more details please refer datasheet.

Programmable Multi-function Transducer - Rish CON M+ - RISHABH
Product Overview

RISH CON-M+ transducer is used to measure 
and convert parameters of a single-phase or 
three-phase AC system with unbalanced or 
balanced load into a proportional load 
independent DC current or DC voltage
output signal.
4-in-1 programmable transducer
Fully onsite programmable Input: 
PT&CT ratio,Output: DC Current/Voltage
Upto 4 Isolated Analog & 2 Relay Output
True RMS and THD measurement upto 31st Harmonics
For more details please refer datasheet.

Programable Multifunction Transducer - Mxx Series - RISHABH
Product Overview

The RISH Ducer MXX series of multi-transducers 
simultaneously measure several variables of an 
electric power system and process them to produce 
2 or 3 or 4 analogue output signals. 2 or 4 digital
outputs are available for signaling limits or power
metering. For two of the limit outputs up to 3 
measurands can be logically combined.
For all heavy-current power system variables
Up to 6 outputs (2A + 4D or 4A + 2D or 2A or 3A
Input voltage up to 693 V (phase-to-phase)
Universal analogue outputs (programmable)
Provision for either snapping the transducer onto top
hat rails or securing it with screws to a wall or pan
For more details please refer datasheet.

Multi Transducer - Rish CON M-40/ M-04/ M-22 - RISHABH
Product Overview

The RISH CON-M transducer is used to measure 
and convert parameter of Three-phase 3W/4W 
AC power network with balanced/unbalanced system.
True RMS measurement.
4-in-1 programmable transducer
Programmable parameters through the RS-485 interface
or USB when using the free eCon configuration software
Fast and easy installation on DIN RAIL or onto a wall or 
ina panel using optional screw hole bracket
Connection Terminal: Conventional Screw type
Detection and signaling of incorrect phase sequence.
For more details please refer datasheet.

Dual Output Transducer - Rish CON CA /CON CV - RISHABH
Product Overview

The transducer RISH CON-CA/CV converts a sinusoidal  
AC Current or AC Voltage into a load independent 
DC Current or a load independent DC Voltage 
proportional to the measured value.
AC Voltage/ Current input signal,sine wave.
Auxiliary Power Supply
Accept any input between 40...300 V AC/DC
Analog Output
Isolated analog output, which can be Voltage or Current.
LED Indication
LED indication for power ON.
For more details please refer datasheet.
 

Current Transformers with Transducer - Rish CT Ducer - RISHABH
Product Overview

Current Transformers With Transducer 
for the measurement of AC current. 
Rish CT Ducer a very reliable, efficient 
and robust current transformer for measurement 
of AC current. It provides 4 to 20 mA
Single device serves functionality of both current
transformer as well as transducer
Measurement of AC current for frequency 50/60Hz 
,Provides proportional 4 - 20 mA or 0-20 mA DC output
High output load resistance up to 1000 ohm
True RMS and Average type models
For more details please refer datasheet.
 

Programmable Single output DC Isolator - RISH PI-101 - RISHABH
Product Overview

The purpose of the RISH PI-101 is to electrically 
isolate input, output and power supply. 
The isolator fulfills all requirements 
and regulation concerning electromagnetic 
compatibility EMC and safety.
User programmable using DIP Switches
Response time < 50 msec
Accuracy Class - 0.2
Auxiliary Supply - 60-300 V AC/DC
                 - 20-40 V AC /20-60 V DC
LED  provided for status indication
For more details please refer datasheet.

Isolating Amplifier Unipolar/Bipolar - Rish ducer TV808 - RISHABH
Product Overview

The purpose of the RISH Ducer TV 808  is to 
electrically insulate input and output signals, 
respectively to amplify and/or change the signal 
level or type (current or voltage) of the input signals.
252 standard input and output combinations 
selected by soldered jumpers
User - specific input and /or output ranges
Isolating amplifier with one input two 
electrically insulated outputs.
Power supply 24 ... 60 V DC/AC or 85 ... 230 V DC/AC
please request our data sheet TV 808 - 11 Le 
For more details please refer datasheet.

Programmable Tap Position Transducer - RISH CON TPT - RISHABH
Product Overview

Tap position transducer RISH CON TPT 
coverts resistance to proportional 
analogue output signal. The purpose of the 
Tap position transducer is to convert tap position
of transformers to equivalent analogue output. 
Outputs can be given as input to either 
RTU or indicator or recording instrument.
Input measuring range can be programmed using 
PC/Simplifies project planning and engineering 
(the final range can be determined during commissioning).
Electrically isolated Dual out puts.
Tap number is programmable from 1 to 101 using software.
For more details please refer datasheet.

Programmable Universal Transmitter - Rish Ducer V604 - RISHABH
Product Overview

The universal transmitter RISH Ducer V 604 
converts the input variable–a DC current or voltage, 
or a signal from a thermocouple,resistance thermometer, 
remote sensor or potentiometer – to a 
proportional analogue output signal.
Input variable (temperature, variation of resistance,DC
signal) and measuring range programmed using PC /
Simplifies project planning and engineering (the final
measuring range can be determined during commissioning).
Short delivery times and low stocking levels
Electric insulation between measured variable,analogue output
signal and power supply / Safe isolation acc. to EN 61 010
For more details please refer datasheet.

Configurable Transmitter - Rish ducer PT602 - RISHABH
Product Overview

The Transmitter RISH Ducer PT 602 
Converts the input variable-a signal from 
a resistance thermometer Pt 100- to a 
temperature linear output signal.
The analogue output signal is either an impressed
current or superimposed voltage which is processed 
by other devices for purposes of displaying, 
recording and / or regulating a constant.
Non - Standard user - specific ranges available
Red LED's indicator : an open or short - circuit.
Electric isolation between input & output 2.3 kV and 
power supply & all other circuits 3.7kV-Fulfils EN 61 010.
For more details please refer datasheet.